Model Alternator R.P.M. P.R.P. Standby legislation / regulation
Model: HYW-9 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 9.9 Standby: 10.7 legislation / regulation: View model
Model: HYW-9 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 10.7 Standby: 11.7 legislation / regulation: View model
Model: HYW-14 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 15.2 Standby: 16.6 legislation / regulation: View model
Model: HYW-14 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 16.2 Standby: 17.5 legislation / regulation: View model
Model: HYW-20 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 20 Standby: 22 legislation / regulation: View model
Model: HYW-20 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 21 Standby: 23 legislation / regulation: View model
Model: HYW-25 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 24 Standby: 26 legislation / regulation: INT. TIER IV View model
Model: HYW-25 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 26 Standby: 28 legislation / regulation: INT. TIER IV View model
Model: HYW-35 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 40 Standby: 44 legislation / regulation: View model
Model: HYW-35 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 40 Standby: 44 legislation / regulation: View model
Model: HYW-35 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 41 Standby: 46 legislation / regulation: View model
Model: HYW-45 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 50 Standby: 55 legislation / regulation: View model
Model: HYW-45 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 50 Standby: 55 legislation / regulation: View model
Model: HYW-45 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 51 Standby: 56 legislation / regulation: View model
Model: HYW-45 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 51 Standby: 56 legislation / regulation: View model
Model: HYW-65 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 60 Standby: 67 legislation / regulation: View model
Model: HYW-65 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 65 Standby: 71 legislation / regulation: View model
Model: HYW-65 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 73 Standby: 80 legislation / regulation: View model
Model: HYW-85 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 74 Standby: 82 legislation / regulation: View model
Model: HYW-65 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 75 Standby: 83 legislation / regulation: View model
Model: HYW-85 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 76 Standby: 84 legislation / regulation: View model
Model: HYW-85 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 90 Standby: 99 legislation / regulation: View model
Model: HYW-85 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 92 Standby: 101 legislation / regulation: View model
Model: HYW-120 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 127 Standby: 139 legislation / regulation: View model
Model: HYW-120 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 132 Standby: 144 legislation / regulation: View model
Model: HYW-155 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 172 Standby: 190 legislation / regulation: View model
Model: HYW-155 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 177 Standby: 196 legislation / regulation: View model
Model: HYW-155 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 179 Standby: 194 legislation / regulation: View model
Model: HYW-155 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 180 Standby: 196 legislation / regulation: View model
Model: HYW-200 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 205 Standby: 226 legislation / regulation: View model
Model: HYW-200 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 206 Standby: 227 legislation / regulation: View model
Model: HYW-200 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 226 Standby: 249 legislation / regulation: View model
Model: HYW-200 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 229 Standby: 252 legislation / regulation: View model
Model: HYW-250 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 294 Standby: 323 legislation / regulation: View model
Model: HYW-250 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 300 Standby: 329 legislation / regulation: View model
Model: HYW-375 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 422 Standby: 464 legislation / regulation: View model
Model: HYW-375 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 428 Standby: 473 legislation / regulation: View model
Model: HYW-440 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 500 Standby: 550 legislation / regulation: View model
Model: HYW-440 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 510 Standby: 563 legislation / regulation: View model
Model: HYW-550 T6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 618 Standby: 681 legislation / regulation: View model
Model: HYW-550 T6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 625 Standby: 690 legislation / regulation: View model
Model Alternator R.P.M. P.R.P. Standby legislation / regulation
Model: HYW-9 M6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 7.8 Standby: 8.5 legislation / regulation: View model
Model: HYW-9 M6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 8.1 Standby: 8.8 legislation / regulation: View model
Model: HYW-14 M6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 12.1 Standby: 13.3 legislation / regulation: View model
Model: HYW-14 M6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 12.3 Standby: 13.5 legislation / regulation: View model
Model: HYW-20 M6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 16.1 Standby: 17.6 legislation / regulation: View model
Model: HYW-20 M6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 17.6 Standby: 19.3 legislation / regulation: View model
Model: HYW-25 M6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 21 Standby: 23 legislation / regulation: INT. TIER IV View model
Model: HYW-25 M6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 22 Standby: 24 legislation / regulation: INT. TIER IV View model
Model: HYW-35 M6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 31 Standby: 34 legislation / regulation: View model
Model: HYW-35 M6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 31 Standby: 34 legislation / regulation: View model
Model: HYW-35 M6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 32 Standby: 35 legislation / regulation: View model
Model: HYW-45 M6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 37 Standby: 40 legislation / regulation: View model
Model: HYW-45 M6 Alternator: STAMFORD R.P.M.: 1.800 P.R.P.: 37 Standby: 40 legislation / regulation: View model
Model: HYW-45 M6 Alternator: MECC ALTE R.P.M.: 1.800 P.R.P.: 40 Standby: 44 legislation / regulation: View model